| Description | Design Code |
Pattern Size |
Pattern Surface Coverage | Max. Size | Solar Trans. (%) |
Visible Light Trans. (%) |
U-Factor BTU/hr-ft-F |
SC | SHGC |
|---|---|---|---|---|---|---|---|---|---|
| Diamond Lines | PS700 | 46 x 108 | 57 | 67 | - | 0.63 | 0.55 | ||
| Diagonals | PS710 | 46 x 108 | 50 | 62 | - | 0.63 | 0.55 | ||
| Squares | PS720 | 46 x 108 | 51 | 68 | - | 0.52 | 0.45 | ||
| Verticals | PS730 | 46 x 108 | 48 | 69 | - | 0.75 | 0.65 | ||
| Basket Weave | PS740 | 46 x 108 | 66 | 53 | - | 0.75 | 0.65 | ||
| Pin Stripes | PS750 | 46 x 108 | 47 | 59 | - | 0.63 | 0.55 | ||
| Horizontal | PS760 | 46 x 108 | 45 | 66 | - | 0.52 | 0.45 | ||
| Half Squares | PS770 | 46 x 108 | 52 | 61 | - | 0.63 | 0.55 | ||
| Venetian | PS780 | 46 x 108 | 54 | 68 | - | 0.75 | 0.65 | ||
| Offset Squares | PS790 | 46 x 108 | 58 | 54 | - | 0.80 | 0.70 | ||
| Dots | PS800 | 46 x 108 | 58 | 76 | - | 0.75 | 0.65 | ||
| Reverse Dots | PS810 | 46 x 108 | 50 | 64 | - | 0.57 | 0.50 | ||
| Horizontal Stripes | PS820 | 46 x 108 | 56 | 72 | - | 0.63 | 0.55 | ||
| Reverse Squares | PS830 | 46 x 108 | 57 | 82 | - | 0.69 | 0.60 | ||
| Vertical Stripes | PS840 | 46 x 108 | 58 | 73 | - | 0.69 | 0.60 |
PLEASE NOTE:
This information is to help you and your customers understand the difference among various types of glazing, so the right choice is made for the specific application. Arch Deco Glass® assumes no responsibility for it's use. The above data was accumulated and calculated at Arch Deco Glass® utilizing the following
methods and meters with a +/- 3% tolerance.
SOLAR HEAT GAIN
a. EDTM model number SP2065 Digital Solar Meter Power/Transmission.
b. Calculated at 20 BTU/HR*FT
c. Light Source = 20 BTU/HR FT
UV BLOCK
a. EDTM model number UV1365E UV Transmission & Power Meter.
b. Calculated as the percent blocked.
c. Calibration source 370 nm ultra violet.
VISIBLE LIGHT
a. EDTM model number VP 1165 Visible Light Transmission & Power Meter.
b. Calculated as the percent of visible light passing through the glass.
c. Calibrated at 100% Light Source.
SOLAR TRANSMISSION
a. EDTM model number SP2065 Digital Solar Meter Power/Transmission.
b. Calculated as the percent of Solar Transmission.
c. Calibrated 100% Infrared Lamp.
SHADING COEFFICIENT
Shading Coefficient of any glass is defined as the ratio of the Solar Heat Gain of the glass to the Solar Heat Gain of 1/8" (3.0mm).